Oil Tanks, Fuel Stations, Oil Recycling Banks from RPM Fuels & Tanks

Products - Bunded Fuel Stations

Home » Products » Bunded Fuel Stations
1400FS Bunded Fuel Station Diesel Tank

1400FS Bunded Fuel Station Diesel Tank

Height: 1850 mm
Diameter: 1570 mm
Capacity: 1413 litres

Plastic bunded storage and dispensing tank suitable for use with diesel fuel. Supplied complete with Automatic Nozzle; choice of 12v, 24v, 110v or 240v Pump; Optional Factory Fitted Mechanical Flow Meter; Lockable Access; Bulkhead Light (240v versions only); Electronic Tank Level Gauge; Bund Alarm; 4 metre Fuel Resistant Delivery Hose; Failsafe Overfill Prevention Capability; 10 micron Filter; Battery Fly Leads (12v/24v only); and, Emergency Isolation Switch.

All Harlequin Plastic Bunded Fuel Storage and Dispensing Tanks are fully compliant with all relevant requirements contained within The Control of Pollution (Oil Storage) (England) Regulations 2001, The Water Environment (Oil Storage) (Scotland) Regulations 2006, Pollution Prevention Guidelines PPG2 and all comparable requirements throughout the United Kingdom, Republic of Ireland, Channel Islands and Isle of Man.

2500FS Bunded Fuel Station Diesel Tank

2500FS Bunded Fuel Station Diesel Tank

Height: 1800 mm
Diameter: 2090 mm
Capacity: 2547 litres

Plastic bunded storage and dispensing tank suitable for use with diesel fuel. Choice of 12v, 24v, 110v or 240 v Pump; Bulkhead Light (240v only); 4 metre Flexible Delivery Hose c/w Automatic Nozzle; Flow Meter; Remote Electronic Gauge; Bund Warning Alarm; Lockable Access; Failsafe Overfill Warning Capability; Overfill Alarm; Emergency Isolation Switch; 10 micron Filter; and, Battery Fly Leads (12v/24v only).

All Harlequin Plastic Bunded Fuel Storage and Dispensing Tanks are fully compliant with all relevant requirements contained within The Control of Pollution (Oil Storage) (England) Regulations 2001, The Water Environment (Oil Storage) (Scotland) Regulations 2006, Pollution Prevention Guidelines PPG2 and all comparable requirements throughout the United Kingdom, Republic of Ireland, Channel Islands and Isle of Man.

5000FS Bunded Fuel Station Diesel Tank

5000FS Bunded Fuel Station Diesel Tank

Height: 2500mm
Length: 2950mm
Width: 2520mm
Capacity: 5042 litres

Plastic bunded storage and dispensing tank suitable for use with diesel fuel. Supplied complete with Choice of 12v, 24v, 110v or 240 v Pump; Bulkhead Light (240v only); 6 metre Flexible Delivery Hose c/w Automatic Nozzle; Flow Meter; 10 micron Filter; Remote Electronic Gauge; Bund Warning Alarm; Lockable Cabinet; Failsafe Overfill Prevention Capability; Overfill Warning Alarm; Emergency Isolation Switch; and, Battery Fly Leads (12v/24v only).

Eighty user fuel management system available on 240 volt models at additional cost.

All Harlequin Plastic Bunded Fuel Storage and Dispensing Tanks are fully compliant with all relevant requirements contained within The Control of Pollution (Oil Storage) (England) Regulations 2001, The Water Environment (Oil Storage) (Scotland) Regulations 2006, Pollution Prevention Guidelines PPG2 and all comparable requirements throughout the United Kingdom, Republic of Ireland, Channel Islands and Isle of Man.

10000FS Bunded Fuel Station

10000FS Bunded Fuel Station

Height: 3350 mm
Length: 3250 mm
Width: 2800 mm
Capacity: 9595 litres

Plastic bunded storage and dispensing tank suitable for use with diesel fuel. Supplied complete with Choice of 12v, 24v, 110v or 240 v Pump; Bulkhead Light (240v only); 6 metre Flexible Delivery Hose c/w Automatic Nozzle; Flow Meter; 10 micron Filter; Remote Electronic Gauge; Bund Warning Alarm; Lockable Cabinet; Failsafe Overfill Prevention Capability; Overfill Warning Alarm; Emergency Isolation Switch; and, Battery Fly Leads (12v/24v only).

Eighty user fuel management system available on 240 volt models at additional cost.

All Harlequin Plastic Bunded Fuel Storage and Dispensing Tanks are fully compliant with all relevant requirements contained within The Control of Pollution (Oil Storage) (England) Regulations 2001, The Water Environment (Oil Storage) (Scotland) Regulations 2006, Pollution Prevention Guidelines PPG2 and all comparable requirements throughout the United Kingdom, Republic of Ireland, Channel Islands and Isle of Man.

All Harlequin Bunded Fuel Station diesel storage and dispensing tanks must be installed and maintained by a competent person, in accordance with manufacturer’s instructions and prevailing statutory requirements. All electrical work must be undertaken and regularly inspected by an appropriately qualified electrician. Clarehill Plastics Limited will not be responsible for installations that do not conform to these requirements. Please note that all images are supplied for reference purposes only and do not necessarily constitute an acceptable installation. If you have any queries, please contact your local environmental authority or a competent, registered installer. All dimensions stated are approximate and noted capacities are nominal and equivalent to 95% of brimful volume.

Website design, management and promotion by Harlequin. © Clarehill Plastics Limited 1999 - 2008.